These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: One-year follow-up of the Melody transcatheter pulmonary valve multicenter post-approval study. Author: Armstrong AK, Balzer DT, Cabalka AK, Gray RG, Javois AJ, Moore JW, Rome JJ, Turner DR, Zellers TM, Kreutzer J. Journal: JACC Cardiovasc Interv; 2014 Nov; 7(11):1254-62. PubMed ID: 25459038. Abstract: OBJECTIVES: This study sought to confirm that the short-term hemodynamic effectiveness of the Melody transcatheter pulmonary valve (TPV) (Medtronic, Inc., Minneapolis, Minnesota) achieved by real-world providers is equivalent to the historical results established in the initial 5-center Investigational Device Exemption trial. BACKGROUND: TPV replacement has been used to treat right ventricular outflow tract (RVOT) conduit dysfunction for >10 years. The Melody TPV received U.S. Food and Drug Administration approval in 2010 as a Humanitarian Use Device. METHODS: Patients with dysfunctional RVOT conduits were entered in this prospective, nonrandomized study at 10 centers. The primary endpoint was acceptable hemodynamic function at 6 months post-implantation, defined as a composite of RVOT echocardiographic mean gradient ≤30 mm Hg, pulmonary regurgitation less than moderate as measured by echocardiography, and freedom from conduit reintervention and reoperation. RESULTS: Cardiac catheterization was performed in 120 patients for potential implantation of the Melody TPV; of these, 100 patients were implanted, with a 98.0% procedural success rate. There were no procedure-related deaths. Acceptable hemodynamic function at 6 months was achieved in 96.7% of patients with evaluable data (87.9% of the entire implanted cohort), with results maintained through 1 year. No patient had moderate or severe pulmonary regurgitation after implantation. No patient required catheter reintervention in the first year after implantation, and 2 patients required reoperation for conduit replacement. The rate of freedom from TPV dysfunction was 96.9% at 1 year. CONCLUSIONS: This first prospective, real-world experience with the Melody TPV in the United States demonstrates continued high procedural success, excellent short-term TPV function, and low reintervention and reoperation rates at 1 year. (Melody Transcatheter Pulmonary Valve Post-Approval Study; NCT01186692).[Abstract] [Full Text] [Related] [New Search]