These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Uniaxial and biaxial mechanical properties of porcine linea alba. Author: Cooney GM, Moerman KM, Takaza M, Winter DC, Simms CK. Journal: J Mech Behav Biomed Mater; 2015 Jan; 41():68-82. PubMed ID: 25460404. Abstract: Incisional hernia is a severe complication post-laparoscopic/laparotomy surgery that is commonly associated with the linea alba. However, the few studies on the mechanical properties of the linea alba in the literature appear contradictory, possible due to challenges with the physical dimensions of samples and variations in protocol. This study focuses on the tensile mechanical characterisation of the porcine linea alba, as determined by uniaxial and equi-load biaxial testing using image-based strain measurement methods. Results show that the linea alba demonstrated a non-linear elastic, anisotropic behaviour which is often observed in biological soft tissues. The transverse direction (parallel to fibres) was found to be approximately eight times stiffer than the longitudinal (cross-fibre) direction under both uniaxial and equi-load biaxial loading. The equi-load biaxial tensile tests revealed that contraction could occur in the transverse direction despite increasing load, probably due to the anisotropy of the tissue. Optical surface marker tracking and digital image correlation methods were found to greatly improve the accuracy of stretch measurement, resulting in a 75% change in the apparent stiffness compared to using strain derived from machine cross-head displacement. Additionally, a finite element model of the experiments using a combination of an Ogden and fibre exponential power law model for the linea alba was implemented to quantify the effect of clamping and tissue dimensions (which are suboptimal for tensile testing) on the results. The preliminary model results were used to apply a correction factor to the uniaxial experimental data prior to inverse optimisation to derive best fit material parameters for the fibre reinforced Ogden model. Application of the model to the equi-load biaxial case showed some differences compared to the experimental data, suggesting a more complex anisotropic model may be necessary to capture biaxial behaviour. These results provide an improved assessment of the mechanical properties of the porcine linea alba for wound closure and other studies.[Abstract] [Full Text] [Related] [New Search]