These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Can sTREM-1 predict septic shock & death in late-onset neonatal sepsis? A pilot study. Author: Arízaga-Ballesteros V, Alcorta-García MR, Lázaro-Martínez LC, Amézquita-Gómez JM, Alanís-Cajero JM, Villela L, Castorena-Torres F, Lara-Díaz VJ. Journal: Int J Infect Dis; 2015 Jan; 30():27-32. PubMed ID: 25461656. Abstract: BACKGROUND AND OBJECTIVES: The transmembrane glycoprotein TREM-1 triggers an inflammatory response. Its soluble fraction (sTREM-1) has been shown to have diagnostic accuracy for late-onset neonatal sepsis (LONS). Until now, the potential of sTREM-1 to predict septic shock and/or death in septic neonates has not been explored. This study obtained estimates of the incidence and prevalence of septic shock and/or death in septic neonates for future sample size calculations for confirmatory studies and evaluated the feasibility of using sTREM-1 as a predictor of septic shock and/or death in neonates with LONS criteria. STUDY DESIGN: A pilot study with a cross-sectional design was performed from May 1(st) to October 31(st), 2012. The participants were hospitalized neonates who, after three days of life, were diagnosed as having LONS. Plasma sTREM-1 was quantified by ELISA. The main outcome measurement was the development of septic shock and/or death. RESULTS: Of 71 eligible subjects, nine (12.7%) progressed to septic shock and/or death. In the LONS-Non-Shock group, the sTREM-1 median and interquartile range (IQR) plasma value were 10 (10 to 70) pg/mL. In the LONS & Shock/Death group, the values were 567 (260 to 649) pg/mL. These values were significantly different (Mann-Whitney's U test, p=0.001). A ROC curve for a proposed sTREM-1 cut-off value of 300 pg/mL exhibited an area under the curve of 0.884 (95% CI=0.73 to 1.0; p<0.0001), with a sensitivity of 0.78 (95% CI=0.46 to 0.94) and specificity of 0.97 (95% CI=0.92 to 0.99); PPV would be 0.78 (95% CI=0.46 to 0.94) and NPV 0.97 (95% CI=0.92 to 0.99). CONCLUSIONS: In neonates with LONS, sTREM-1 has the potential to provide an excellent predictive value for septic shock/death. Larger sample sizes are needed to identify the optimal cut-off value of plasma sTREM-1 for this diagnosis and to provide diagnostic accuracy measures.[Abstract] [Full Text] [Related] [New Search]