These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Label-free triple-helix aptamer as sensing platform for "signal-on" fluorescent detection of thrombin. Author: Xu N, Wang Q, Lei J, Liu L, Ju H. Journal: Talanta; 2015 Jan; 132():387-91. PubMed ID: 25476322. Abstract: The design of a label-free aptamer for separation of recognition sequence from signal reporter is significant to ensure the high-efficiency affinity between aptamer and target. This work develops a label-free triple-helix aptamer (THA) as sensing platform for "signal-on" fluorescent detection of thrombin. THA was composed of aptamer sequence and help DNA 1 (H1), which contained the complementary sequence of hexachloro-fluorescein (HEX) labeled help DNA 2 (H2). The specific recognition event between aptamer and thrombin triggered the dismission of THA to release H1. The released H1 then reacted with the signal probe of H2/graphene oxide (GO) nanocomposite to form H1-H2 duplex, leading to the fluorescence recovery of H2 due to the detachment of H1-H2 duplex from the surface of GO. With employment of THA as a signal transducer and GO as a "superquencher", this method shows a sensitive response to thrombin with a wide concentration range from 5 to 1200 nM. The limit of detection is 1.8 nM (S/N=3) with excellent selectivity. Considering the universality of THA, the proposed aptasensor would provide a platform for homogeneous fluorescent detection of a wide range of analytes.[Abstract] [Full Text] [Related] [New Search]