These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: [Clinical study of intra-operative computed tomography guided localization with a hook-wire system for small ground glass opacities in minimally invasive resection]. Author: Chu X, Hou X, Zhang L, Xue Z, Ren Z, Wen J, Liu Y, Ma K, Sun Y. Journal: Zhongguo Fei Ai Za Zhi; 2014 Dec; 17(12):845-9. PubMed ID: 25539609. Abstract: BACKGROUND AND OBJECTIVE: Localization of pulmonary ground glass small nodule is the technical difficulty of minimally invasive operation resection. The aim of this study is to evaluate the value of intraoperative computed tomography (CT)-guided localization using a hook-wire system for small ground glass opacity (GGO) in minimally invasive resection, as well as to discuss the necessity and feasibility of surgical resection of small GGOs (<10 mm) through a minimally invasive approach. METHODS: The records of 32 patients with 41 small GGOs who underwent intraoperative CT-guided double-thorn hook wire localization prior to video-assisted thoracoscopic wedge resection from October 2009 to October 2013 were retrospectively reviewed. All patients received video-assisted thoracoscopic surgery (VATS) within 10 min after wire localization. The efficacy of intraoperative localization was evaluated in terms of procedure time, VATS success rate, and associated complications of localization. RESULTS: A total of 32 patients (15 males and 17 females) underwent 41 VATS resections, with 2 simultaneous nodule resections performed in 3 patients, 3 lesion resections in 1 patient, and 5 lesions in a patient. Nodule diameters ranged from 2 mm-10 mm (mean: 5 mm). The distance of lung lesions from the nearest pleural surfaces ranged within 5 mm-24 mm (mean: 12.5 mm). All resections of lesions guided by the inserted hook wires were successfully performed by VATS (100% success rate). The mean procedure time for the CT-guided hook wire localization was 8.4 min (range: 4 min-18 min). The mean procedure time for VATS was 32 min (range: 14 min-98 min). The median hospital time was 8 d (range: 5 d-14 d). Results of pathological examination revealed 28 primary lung cancers, 9 atypical adenomatous hyperplasia, and 4 nonspecific chronic inflammations. No major complication related to the intraoperative hook wire localization and VATS was noted. CONCLUSIONS: Intraoperative CT-guided hook wire localization is useful, particularly in small GGO localization in VATS wedge resection and has a significantly low rate of minor complications. Lung GGOs carry a 90% risk of malignancy. Aggressive surgical resection of these GGOs is necessary and feasible through the guidance of intraoperative CT localization technique. 背景与目的 肺磨玻璃样微小结节(ground glass opacity, GGO)病灶的定位是微创手术切除的技术难点。各种定位方法均有报道,但每一种方法均有其不足。本研究拟通过评价术中CT引导下Hook-wire定位对GGO微创切除的价值,初步探索肺部<10 mm的GGO积极手术治疗的必要性和可行性。方法 2009年10月-2013年10月共32例GGO患者,41个GGO,行胸腔镜微创切除术,麻醉插管后皆在手术体位下行计算机断层扫描(computed tomography, CT)CT引导Hook-wire定位。记录术中CT引导下Hook-wire定位技术的失败率、并发症、胸腔镜手术转为开胸手术的几率、住院时间等,计算病灶组织学分型中的恶性几率,讨论肺部<10 mm的GGO积极手术治疗的必要性。结果 共32例患者(男性15例,女性17例)行41个GGO胸腔镜微创切除术,其中2个病灶、3个病灶和5个病灶同时微创切除患者数量分别是3例、1例、1例。病灶直径2 mm-10 mm(平均5 mm),病灶距离胸膜垂直距离5 mm-24 mm(平均12.5 mm)。术中CT引导下Hook-wire定位成功率100%,严重并发症发生率0,转化为开胸手术比率为0,CT定位时间平均8.4 min(4 min-18 min),微创切除病灶所需时间平均32 min(14 min-98 min),中位住院时间为8 d(5 d-14 d)。GGOs术后组织学诊断结果为:原位腺癌(肺泡癌)19例,约46.3%,腺癌8例,约19.5%,大细胞癌1例,约2.4%,不典型腺瘤样增生9例,约22%,炎性病灶4例,约9.8%。结论 肺部GGO是恶性病灶的几率很大,对典型GGO患者积极微创手术治疗是非常必要的;术中CT引导下Hook-wire定位技术极大提高GGO微创切除可行性、并发症发生率低,对于GGO的鉴别诊断及治疗具有很好的临床价值。[Abstract] [Full Text] [Related] [New Search]