  • Title: A novel approach for concurrent quantitation of glutathione, glutathione disulfide, and 2-hydroxyethylated glutathione in lungs of mice exposed to ethylene oxide, using liquid chromatography-positive electrospray tandem mass spectrometry.
    Author: Zhang F, Bartels MJ, LeBaron MJ, Schisler MR, Gollapudi BB, Moore NP.
    Journal: Biomed Chromatogr; 2015 Sep; 29(9):1364-74. PubMed ID: 25641649.
    Abstract:
    Glutathione (GSH), glutathione disulfide (GSSG) and 2-hydroxyethylated glutathione (HESG) are important biomarkers for exploring the genotoxicity mechanism of ethylene oxide (EO) or ethylene in vivo. A liquid chromatography-tandem mass spectrometry method was developed for simultaneous determination of GSH, GSSG and HESG in mouse lung tissues after inhalation exposure to EO. The lower limit of quantitation for all these biomarkers was 0.002 µg/mL. The linearity of the calibration curves for all analytes was >0.998. The intra-day assay precision relative standard deviation (RSD) values for quality control samples for all analytes were ≤12.8% with accuracy values ranging from 87.2 to 113%. The inter-day assay precision (RSD) values for all analytes were ≤13.1% with accuracy values ranging from 86.9 to 103%. This method was applied to concurrently determine the levels of GSH, GSSG and HESG in lung samples isolated from mouse after 4-week inhalation exposure to EO at 0, 10, 50, 100 and 200 ppm.