These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: An HPLC method to determine sennoside A and sennoside B in Sennae fructus and Sennae folium.
    Author: Rosenthal I, Wolfram E, Meier B.
    Journal: Pharmeur Bio Sci Notes; 2014; 2014():92-102. PubMed ID: 25655246.
    Abstract:
    INTRODUCTION: The current Ph. Eur. monographs for senna pods, senna leaf and senna leaf dry extract standardised describe a photometric assay based on the Bornträger reaction to determine hydroxyanthracene glycosides, calculated as sennoside B. The method is timeconsuming, unspecific for sennosides and the precision is not adequate for a modern assay. AIM: The photometric method shall therefore be replaced by a modern HPLC method. About 70 % of the total anthrachinone content in herbal drugs of senna species is due to sennoside A and sennoside B. These substances are therefore suitable for the standardisation of Senna products. The Japanese Pharmacopoeia (JP) already describes an HPLC method to determine sennoside A and sennoside B in the monograph for senna leaf. It uses ion-pair chromatography with tetraheptylammoniumbromide. The procedure described in the monograph has a runtime of 70 min. METHOD: The adapted and validated method described here uses solid-phase extraction (SPE) which allows a selective sample preparation by using an anion exchange phase. A conventional RP C18 column Tosh TSKgel ODS-80TS (4.6 mm × 150 mm), 5 μm, was used as stationary phase and acetonitrile for chromatography R, water R, phosphoric acid R (200:800:1 V/V/V) as mobile phase. The flow rate was 1.2 mL/min, the column temperature 40 °C, the detection wavelength 380 nm, and the injection volume 20 μL. The runtime is 10 min, the chromatogram shows 2 peaks due to sennoside A/B and 2 additional smaller compounds. One of them is rhein-8-O-glucoside. RESULTS: The procedure has been successfully validated according to ICH guidelines. We analysed 6 batches of Senna. The pods (Senna angustifolia) showed a total content of sennoside A and B of 1.74-2.76 % m/m and the content of senna leaves was clearly lower with 1.07-1.19 % m/m, respectively. CONCLUSION: The suggested method is considered to be suitable to determine sennoside A and sennoside B in senna leaves and senna pods. The consideration is based on the performed validation and on the results for the analysed samples. A short run time and better resolution are clear advantages of the suggested method, compared to other methods.
    [Abstract] [Full Text] [Related] [New Search]