These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Drug composition matters: the influence of carrier concentration on the radiochemical purity, hydroxyapatite affinity and in-vivo bone accumulation of the therapeutic radiopharmaceutical 188Rhenium-HEDP. Author: Lange R, de Klerk JMH, Bloemendal HJ, Ramakers RM, Beekman FJ, van der Westerlaken MML, Hendrikse NH, Ter Heine R. Journal: Nucl Med Biol; 2015 May; 42(5):465-469. PubMed ID: 25662844. Abstract: INTRODUCTION: (188)Rhenium-HEDP is an effective bone-targeting therapeutic radiopharmaceutical, for treatment of osteoblastic bone metastases. It is known that the presence of carrier (non-radioactive rhenium as ammonium perrhenate) in the reaction mixture during labeling is a prerequisite for adequate bone affinity, but little is known about the optimal carrier concentration. METHODS: We investigated the influence of carrier concentration in the formulation on the radiochemical purity, in-vitro hydroxyapatite affinity and the in-vivo bone accumulation of (188)Rhenium-HEDP in mice. RESULTS: The carrier concentration influenced hydroxyapatite binding in-vitro as well as bone accumulation in-vivo. Variation in hydroxyapatite binding with various carrier concentrations seemed to be mainly driven by variation in radiochemical purity. The in-vivo bone accumulation appeared to be more complex: satisfactory radiochemical purity and hydroxyapatite affinity did not necessarily predict acceptable bio-distribution of (188)Rhenium-HEDP. CONCLUSIONS: For development of new bisphosphonate-based radiopharmaceuticals for clinical use, human administration should not be performed without previous animal bio-distribution experiments. Furthermore, our clinical formulation of (188)Rhenium-HEDP, containing 10 μmol carrier, showed excellent bone accumulation that was comparable to other bisphosphonate-based radiopharmaceuticals, with no apparent uptake in other organs. ADVANCES IN KNOWLEDGE: Radiochemical purity and in-vitro hydroxyapatite binding are not necessarily predictive of bone accumulation of (188)Rhenium-HEDP in-vivo. IMPLICATIONS FOR PATIENT CARE: The formulation for (188)Rhenium-HEDP as developed by us for clinical use exhibits excellent bone uptake and variation in carrier concentration during preparation of this radiopharmaceutical should be avoided.[Abstract] [Full Text] [Related] [New Search]