These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: An LC-MS/MS method for the quantitation of cabozantinib in rat plasma: application to a pharmacokinetic study. Author: Su Q, Li J, Ji X, Li J, Zhou T, Lu W, Li L. Journal: J Chromatogr B Analyt Technol Biomed Life Sci; 2015 Mar 15; 985():119-23. PubMed ID: 25678398. Abstract: A simple, rapid and sensitive high-performance liquid chromatography tandem mass-spectrometric method (LC-MS/MS) for the novel multiple tyrosine kinase inhibitor (TKI) cabozantinib was developed and validated using erlotinib as internal standard (IS). Plasma samples were pre-treated by liquid-liquid extraction with ethyl acetate. Separation was achieved on a reversed phase C18 column (50×2mm, 5μm) at ambient temperature using isocratic elution with acetonitrile-water (45:55, v/v) containing 5mM ammonium formate buffer (finally adjusted to apparent pH*=5.0 with formic acid) at a flow rate of 0.4mL/min. The analytes were monitored by a triple quadrupole tandem mass spectrometer with electrospray ionization source in the positive ion mode. Calibration curve was linear (r>0.99) in a concentration range of 0.5-1000ng/mL with the lower limit of quantification (LLOQ) of 0.5ng/mL. Intra- and inter-day accuracy and precision were validated by relative error values (RE) and relative standard deviation values (RSD), respectively, which were both lower than the limit of 15%. This method was successfully applied to a pharmacokinetic study of cabozantinib in rats.[Abstract] [Full Text] [Related] [New Search]