These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Automated radiosynthesis of GMP quality [18F]HX4 for PET imaging of hypoxia.
    Author: Turton DR, Betts HM, Dutton D, Perkins AC.
    Journal: Nucl Med Biol; 2015 May; 42(5):494-498. PubMed ID: 25725983.
    Abstract:
    INTRODUCTION: [(18)F]HX4 is a 2-nitroimidazole based investigational radiotracer for imaging hypoxia. METHODS: A two-step, one-pot synthetic procedure was developed on a GE Tracerlab MX-FDG with a disposable cassette. Nucleophilic substitution of a nosylate group with [(18)F]fluoride was followed by solvent evaporation and acidic removal of the acetyl protecting group. HPLC purification in a bio-compatible solvent mixture was developed. RESULTS AND CONCLUSIONS: Using starting activities of 80-110 GBq [(18)F]fluoride, GMP compliant [(18)F]HX4 was produced in non-decay corrected radiochemical yields of 12 ± 3% (n = 9) in 55 min including HPLC purification. No reformulation steps were required. The mean specific activity of the final product was 2450 GBq/μmol. Modifications to the process and final formulation were included to prevent decomposition of the product, and these changes resulted in an improved stability of the formulated [(18)F]HX4, with a shelf-life of at least 8h post-synthesis. The product consistently passed all required quality control tests to determine that the [(18)F]HX4 was suitable for clinical use. Using a 90 minute target bombardment, and 80-110 GBq starting [(18)F]fluoride, the method produced multiple patient doses.
    [Abstract] [Full Text] [Related] [New Search]