These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Longitudinal assessment of inflammation in recipients of continuous-flow left ventricular assist devices.
    Author: Grosman-Rimon L, Jacobs I, Tumiati LC, McDonald MA, Bar-Ziv SP, Fuks A, Kawajiri H, Lazarte J, Ghashghai A, Shogilev DJ, Cherney DZ, Rao V.
    Journal: Can J Cardiol; 2015 Mar; 31(3):348-56. PubMed ID: 25746024.
    Abstract:
    BACKGROUND: The long-term effects of continuous-flow left ventricular assist device (CF-LVAD) support on trends of inflammatory markers over time are unknown. We examined the hypothesis that the levels of inflammatory markers in CF-LVAD recipients are higher than in healthy controls and that these levels increase over time with long-term CF-LVAD support. METHODS: We examined the levels of inflammatory markers longitudinally at baseline before CF-LVAD implantation and at 3, 6, and 9 months after implantation. We then compared the levels of inflammatory markers to those in a healthy control group. RESULTS: Compared with baseline values before CF-LVAD implantation, left ventricular end-diastolic diameter (LVEDd) and left ventricular end-systolic diameter (LVESd) decreased significantly at 3, 6, and 9 months after CF-LVAD implantation. Brain natriuretic peptide (BNP) levels dropped significantly after CF-LVAD implantation but did not normalize. Improvements in ejection fraction at 3, 6, and 9 months after CF-LVAD implantation did not reach significance. Monocyte chemoattractant protein-1, interferon γ-induced protein, and C-reactive protein levels were higher in the CF-LVAD recipients at each of the time points (baseline before CF-LVAD implantation and 3, 6, and 9 months after implantation) compared with levels in healthy controls. In CF-LVAD recipients, serum interleukin-8, tumour necrosis factor-α, and macrophage inflammatory protein-β increased significantly at 9 months, and macrophage-derived chemokine increased at 6 months after CF-LVAD implantation compared with baseline. CONCLUSIONS: Despite improvements in LV dimensions and BNP levels, markers of inflammation remained higher in CF-LVAD recipients. High levels of inflammation in CF-LVAD recipients may result from heart failure preconditioning or the long-term device support, or both. Because inflammation may be detrimental to CF-LVAD recipients, future studies should determine whether inflammatory pathways are reversible.
    [Abstract] [Full Text] [Related] [New Search]