These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Superiority of stent-grafts for in-stent restenosis in the superficial femoral artery: twelve-month results from a multicenter randomized trial. Author: Bosiers M, Deloose K, Callaert J, Verbist J, Hendriks J, Lauwers P, Schroë H, Lansink W, Scheinert D, Schmidt A, Zeller T, Beschorner U, Noory E, Torsello G, Austermann M, Peeters P. Journal: J Endovasc Ther; 2015 Feb; 22(1):1-10. PubMed ID: 25775672. Abstract: PURPOSE: To evaluate the short- and midterm outcomes of the Viabahn endoprosthesis with Propaten Bioactive Surface vs. standard balloon angioplasty for treatment of in-stent restenosis in the superficial femoral artery. METHODS: Between June 2010 and February 2012, 83 patients with superficial femoral artery in-stent and Rutherford category 2 to 5 ischemia were enrolled at 7 sites participating in this prospective randomized controlled study (RELINE; ClinicalTrials.gov; identifier NCT01108861). The patients were randomized to treatment with either the heparin-bonded Viabahn endoprosthesis (n = 39: 29 men; mean age 67.7 ± 9.8 years) or a standard angioplasty balloon (n = 44: 32 men; mean age 69.0 ± 9.7 years). The primary effectiveness outcome was primary patency at 12 months, defined as no restenosis/occlusion within the target lesion based on duplex ultrasound and no target lesion revascularization. The primary safety endpoint was the incidence of serious device-related adverse events within 30 days of the procedure. RESULTS: All patients randomized to receive dilation or the Viabahn stent-graft were treated according to their assignment. The technical success was 100% for the Viabahn group and 81.8% for the angioplasty group (p = 0.002) owing to 9 patients requiring a bailout procedure after unsuccessful angioplasty. The 12-month primary patency rates were 74.8% for the Viabahn group and 28.0% for the angioplasty group (p < 0.001). Excluding the 9 angioplasty patients who received bailout stenting, the primary patency for optimal balloon angioplasty was 37.0% (p < 0.001). Three patients experienced device-related adverse events within 30 days: occlusion of the target lesion (Viabahn group), peripheral embolization (angioplasty group), and reocclusion of the target lesion (angioplasty group). CONCLUSION: In this study, the treatment of femoropopliteal in-stent restenosis with a Viabahn endoprosthesis showed significantly better results than treatment with a standard balloon at 1 year.[Abstract] [Full Text] [Related] [New Search]