These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Assessment of baroreflex sensitivity from spontaneous oscillations of blood pressure and heart rate: proven clinical value? Author: Pinna GD, Maestri R, La Rovere MT. Journal: Physiol Meas; 2015 Apr; 36(4):741-53. PubMed ID: 25798657. Abstract: The baroreceptor-heart rate reflex (baroreflex sensitivity, BRS) is a key mechanism contributing to the neural regulation of the cardiovascular system. Several methods have been proposed so far to assess BRS by analyzing the spontaneous beat-to-beat fluctuations of arterial blood pressure and heart rate. These methods are inherently simple, non-invasive and low-cost. This study is an attempt to address the question of whether spontaneous baroreflex methods have proven to be of value in the clinical setting. In the first part of this article, we critically review most representative clinical studies using spontaneous BRS techniques either for risk stratification or treatment evaluation, these being major issues in the clinical management of the patients. In the second part, we address two important aspects of spontaneous BRS measurements: measurability and reliability. Estimation of BRS in the studies selected for the review was performed according to the sequence, transfer function, alpha-index and phase-rectified signal averaging method. Arterial blood pressure was recorded non-invasively during supine, short-term (<30 min) laboratory recordings. The conclusion from this review is that spontaneous BRS techniques have been shown to be of great value in clinical practice but further work is needed to confirm the validity of previous findings and to widen the field of clinical applications. Measurability and reliability can be a major issue in the measurement of spontaneous BRS, particularly in some patient populations like post-myocardial infarction and heart failure patents. Main causes of poor measurability are: non-sinus rhythm, a high rate of ectopic beats and the need for recorded time series of RR interval and arterial blood pressure to satisfy the constraints of the different BRS estimation algorithms. As for reliability, within-subject variability is rather high in the measurements of spontaneous BRS and, therefore, should be carefully taken into account when BRS measurements are used to detect treatment effects in individual patients.[Abstract] [Full Text] [Related] [New Search]