These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Surgical removal of entrapped endocardial leads without using extracorporeal circulation.
    Author: Dubernet J, Irarrázaval MJ, Lema G, Maturana G, Urzúa J, Morán S, Navarro M, Fajuri A.
    Journal: Pacing Clin Electrophysiol; 1985 Mar; 8(2):175-80. PubMed ID: 2580277.
    Abstract:
    Of 267 patients having a tined endocardial lead implanted from 1978 to December 1983, three (1.1%) developed pulse generator pocket infection. Proper treatment of this complication involves removal of the pulse generator, continued external pacing via the implanted lead, pocket drainage and administration of specific antibiotics until the infected area clears. In two patients, the electrode could not be removed by traction. A sternotomy was performed, the pericardium was opened, the endocardial electrode was located by palpation, and a purse string suture (PSS) was prepared around it on the right ventricular wall. A new myocardial electrode with its corresponding generator was then implanted to reestablish pacing. Through the PSS the myocardium was incised, the distal end of the endocardial lead was exteriorized and severed, and the PSS was tied. The remaining lead was withdrawn proximally and the surgical wounds were closed. The results of this procedure have been been excellent, allowing the removal of the entrapped leads, with continuous pacing and without the need for extracorporeal circulation.
    [Abstract] [Full Text] [Related] [New Search]