These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: One-hour rule-in and rule-out of acute myocardial infarction using high-sensitivity cardiac troponin I.
    Author: Rubini Gimenez M, Twerenbold R, Jaeger C, Schindler C, Puelacher C, Wildi K, Reichlin T, Haaf P, Merk S, Honegger U, Wagener M, Druey S, Schumacher C, Krivoshei L, Hillinger P, Herrmann T, Campodarve I, Rentsch K, Bassetti S, Osswald S, Mueller C.
    Journal: Am J Med; 2015 Aug; 128(8):861-870.e4. PubMed ID: 25840034.
    Abstract:
    OBJECTIVE: We aimed to prospectively derive and validate a novel 1h-algorithm using high-sensitivity cardiac troponin I (hs-cTnI) for early rule-out and rule-in of acute myocardial infarction. METHODS: We performed a prospective multicenter diagnostic study enrolling 1811 patients with suspected acute myocardial infarction. The final diagnosis was centrally adjudicated by 2 independent cardiologists using all available information, including coronary angiography, echocardiography, follow-up data, and serial measurements of hs-cTnT (but not hs-cTnI). The hs-cTnI 1h-algorithm, incorporating measurements performed at baseline and absolute changes within 1 hour, was derived in a randomly selected sample of 906 patients (derivation cohort), and then validated in the remaining 905 patients (validation cohort). RESULTS: Acute myocardial infarction was the final diagnosis in 18% of patients. After applying the hs-cTnI 1h-algorithm developed in the derivation cohort to the validation cohort, 50.5% of patients could be classified as "rule-out," 19% as "rule-in," 30.5% as "observe." In the validation cohort, the negative predictive value for acute myocardial infarction in the "rule-out" zone was 99.6% (95% confidence interval, 98.4%-100%), and the positive predictive value for acute myocardial infarction in the "rule-in" zone was 73.9% (95% confidence interval, 66.7%-80.2%). Negative predictive value of the 1h-algorithm was higher compared with the classical dichotomous interpretation of hs-cTnI and to the standard of care combining hs-cTnI with the electrocardiogram (both P < .001). Positive predictive value also was higher compared with the standard of care (P < .001). CONCLUSION: Using a simple algorithm incorporating baseline hs-cTnI values and the absolute change within the first hour allows safe rule-out as well as accurate rule-in of acute myocardial infarction in 70% of patients presenting with suspected acute myocardial infarction.
    [Abstract] [Full Text] [Related] [New Search]