These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Inexplicable late type Ia endoleak associated with the low-profile Ovation endograft in a patient with favorable neck anatomy: treatment with transcaval coil embolization.
    Author: Gandini R, Del Giudice C, Abrignani S, Vasili E, Pampana E, Simonetti G.
    Journal: J Endovasc Ther; 2015 Jun; 22(3):426-30. PubMed ID: 25862362.
    Abstract:
    PURPOSE: To report an unusual late type Ia endoleak after endovascular aneurysm repair with a low-profile sealing ring endograft and its treatment with transcaval sac embolization. CASE REPORT: An 82-year-old man was treated for a 47-mm abdominal aortic aneurysm associated with a 35-mm left common iliac artery aneurysm using an Ovation Abdominal Stent Graft System. Correct endograft placement was documented at 3-month follow-up. Seven months after the repair, the patient was admitted to the emergency department with acute left inguinal pain. Computed tomography showed aneurysm sac enlargement (57 mm) and a contained rupture of the left common iliac artery due to a late type Ia endoleak. The endoleak was embolized with coils and thrombin via a transcaval approach. Sac shrinkage without signs of endoleak was observed at 12-month follow-up. CONCLUSION: In this case, late endograft failure with sealing ring collapse created an inflow channel into the aneurysm sac, with massive type Ia endoleak.
    [Abstract] [Full Text] [Related] [New Search]