These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: CT evaluation prior to transapical aortic valve replacement: semi-automatic versus manual image segmentation. Author: Foldyna B, Jungert C, Luecke C, von Aspern K, Boehmer-Lasthaus S, Rueth EM, Grothoff M, Nitzsche S, Gutberlet M, Mohr FW, Lehmkuhl L. Journal: Int J Cardiovasc Imaging; 2015 Aug; 31(6):1233-42. PubMed ID: 25893746. Abstract: To compare the performance of semi-automatic versus manual segmentation for ECG-triggered cardiovascular computed tomography (CT) examinations prior to transcatheter aortic valve replacement (TAVR), with focus on the speed and precision of experienced versus inexperienced observers. The preoperative ECG-triggered CT data of 30 consecutive patients who were scheduled for TAVR were included. All datasets were separately evaluated by two radiologists with 1 and 5 years of experience (novice and expert, respectively) in cardiovascular CT using an evaluation software program with or without a semi-automatic TAVR workflow. The time expended for data loading and all segmentation steps required for the implantation planning were assessed. Inter-software as well as inter-observer reliability analysis was performed. The CT datasets were successfully evaluated, with mean duration between 520.4 ± 117.6 s and 693.2 ± 159.5 s. The three most time-consuming steps were the 3D volume rendering, the measurement of aorta diameter and the sizing of the aortic annulus. Using semi-automatic segmentation, a novice could evaluate CT data approximately 12.3% faster than with manual segmentation, and an expert could evaluate CT data approximately 10.3% faster [mean differences of 85.4 ± 83.8 s (p < 0.001) and 59.8 ± 101 s (p < 0.001), respectively]. The inter-software reliability for a novice was slightly lower than for an expert; however, the reliability for a novice and expert was excellent (ICC 0.92, 95% CI 0.75-0.97/ICC 0.96, 95% CI 0.91-0.98). Automatic aortic annulus detection failed in two patients (6.7%). The study revealed excellent inter-software and inter-observer reliability, with a mean ICC of 0.95. TAVR evaluation can be accomplished significantly faster with semi-automatic rather than with manual segmentation, with comparable exactness, showing a benefit for experienced and inexperienced observers.[Abstract] [Full Text] [Related] [New Search]