These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Endocan-1 concentrations in maternal and fetal plasma and placentae in pre-eclampsia in the third trimester of pregnancy. Author: Hentschke MR, Lucas LS, Mistry HD, Pinheiro da Costa BE, Poli-de-Figueiredo CE. Journal: Cytokine; 2015 Jul; 74(1):152-6. PubMed ID: 25957465. Abstract: INTRODUCTION: Endocan-1 has been proposed as a possible biomarker and predictor of vascular endothelial related pathologies. Thus, we hypothesised that Endocan-1 levels would be up-regulated in maternal plasma and placentae from women with pre-eclampsia. The aim of our study was to compare Endocan-1 concentrations in maternal/fetal plasma and placentae from normotensive and pre-eclamptic pregnancies. METHODS: Observational and case-controlled study, at the São Lucas Hospital, Brazil. Placental biopsies, maternal/umbilical venous (fetal) plasma were taken from 67 normotensive and 50 pre-eclamptic women. Endocan-1 levels were quantified using MagPlex(TH)-C and analysed by Analysis of Covariance and Pearson correlation. The null hypothesis was rejected at p<0.05. RESULTS: Higher levels of Endocan-1 were found in maternal plasma in the pre-eclamptic group (mean ratio=1.49; 95% confidence interval: 1.19-1.85, p=0.001), with a moderate effect size (Cohen's D=0.84). Placental Endocan-1 levels (μg/g) were lower in pre-eclampsia (1.52 [1.10, 2.40] vs. 2.24 [1.32, 3.75], p=0.033) and fetal Endocan-1 concentration (ng/ml) did not show any difference between groups (3.10 [2.60, 4.54] vs. 2.91 [2.20, 3.66] p=0.085). In addition, an up-regulation of maternal plasma Endocan-1 in the pre-eclamptic group was observed when stratified in relation to gestational age, systolic blood pressure and proteinuria (p<0.05, for all). Furthermore, a positive correlation between Endocan-1 concentration in maternal vs. fetal plasma was also found (r=0.258, p=0.015). For the matched samples, a negative correlation between Endocan-1 in maternal/fetal plasma with birthweights, placental weights and gestational age at delivery was observed (p<0.05 for all). DISCUSSION: Endocan-1 is increased in women with pre-eclampsia for all strata, which highlight the importance of this molecule as a possible biomarker. The negative correlations between Endocan-1 and clinical data suggest that this molecule may also be involved with prematurity and low birth weight, which warrants further investigations.[Abstract] [Full Text] [Related] [New Search]