These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Predictors of adverse neonatal outcomes in intrahepatic cholestasis of pregnancy.
    Author: Kawakita T, Parikh LI, Ramsey PS, Huang CC, Zeymo A, Fernandez M, Smith S, Iqbal SN.
    Journal: Am J Obstet Gynecol; 2015 Oct; 213(4):570.e1-8. PubMed ID: 26071912.
    Abstract:
    OBJECTIVE: We sought to determine predictors of adverse neonatal outcomes in women with intrahepatic cholestasis of pregnancy (ICP). STUDY DESIGN: This study was a multicenter retrospective cohort study of all women diagnosed with ICP across 5 hospital facilities from January 2009 through December 2014. Obstetric and neonatal complications were evaluated according to total bile acid (TBA) level. Multivariable logistic regression models were developed to evaluate predictors of composite neonatal outcome (neonatal intensive care unit admission, hypoglycemia, hyperbilirubinemia, respiratory distress syndrome, transient tachypnea of the newborn, mechanical ventilation use, oxygen by nasal cannula, pneumonia, and stillbirth). Predictors including TBA level, hepatic transaminase level, gestational age at diagnosis, underlying liver disease, and use of ursodeoxycholic acid were evaluated. RESULTS: Of 233 women with ICP, 152 women had TBA levels 10-39.9 μmol/L, 55 had TBA 40-99.9 μmol/L, and 26 had TBA ≥100 μmol/L. There was no difference in maternal age, ethnicity, or prepregnancy body mass index according to TBA level. Increasing TBA level was associated with higher hepatic transaminase and total bilirubin level (P < .05). TBA levels ≥100 μmol/L were associated with increased risk of stillbirth (P < .01). Increasing TBA level was also associated with earlier gestational age at diagnosis (P < .01) and ursodeoxycholic acid use (P = .02). After adjusting for confounders, no predictors were associated with composite neonatal morbidity. TBA 40-99.9 μmol/L and TBA ≥100 μmol/L were associated with increased risk of meconium-stained amniotic fluid (adjusted odds ratio, 3.55; 95% confidence interval, 1.45-8.68 and adjusted odds ratio, 4.55; 95% confidence interval, 1.47-14.08, respectively). CONCLUSION: In women with ICP, TBA level ≥100 μmol/L was associated with increased risk of stillbirth. TBA ≥40 μmol/L was associated with increased risk of meconium-stained amniotic fluid.
    [Abstract] [Full Text] [Related] [New Search]