These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: SmartArc-based volumetric modulated arc therapy can improve the middle ear, vestibule and cochlea sparing for locoregionally advanced nasopharyngeal carcinoma: a dosimetric comparison with step-and-shoot intensity-modulated radiotherapy. Author: Gao J, Qian TL, Tao CZ, Zhang YH, Zhou Y, Yang J, He J, Wang R, Zhou PJ. Journal: Br J Radiol; 2015 Sep; 88(1053):20150052. PubMed ID: 26111068. Abstract: OBJECTIVE: Radiation-induced sensorineural hearing loss is a common complication after radiotherapy in patients with nasopharyngeal carcinoma (NPC) that significantly affects their quality of life. The goal of this study was to compare SmartArc-based volumetric modulated arc therapy (VMAT-S) with step-and-shoot intensity-modulated radiation therapy (IMRT) for patients with locoregionally advanced NPC with regard to the sparing effect on middle ear, vestibule and cochlea. METHODS: 20 patients with non-metastatic Stage III or IV NPC were selected to have planning with VMAT-S and IMRT [using Philips Pinnacle Planning System (Philips, Fitchburg, WI) for Varian accelerator] for dosimetric comparison. Mean middle ears, vestibule and cochlea doses for the two planning techniques were compared using a paired t-test. Target coverage and dose homogeneity were evaluated by calculating conformity index (CI) and homogeneity index (HI) values. RESULTS: VMAT-S had significantly improved homogeneity and conformity compared with IMRT. Mean HI of planning target volume of gross tumour volume (PGTV) was better with VMAT-S (1.05 ± 0.02) than IMRT (1.09 ± 0.03) (p < 0.001). Mean CI of PGTV is also better with VMAT-S (0.59 ± 0.12) than IMRT (0.54 ± 0.12) (p < 0.001). Mean doses to the left cochleas were 43.8 ± 3.6 and 47.8 ± 4.0 (p < 0.001) for VMAT-S and IMRT plans, respectively. Mean doses to the right cochleas were 42.7 ± 4.7 and 47.6 ± 5.4 (p < 0.001) for VMAT-S and IMRT plans, respectively. VMAT-S also significantly reduced the mean doses to middle ears (p < 0.001 for both) and vestibule (p < 0.001 for both). CONCLUSION: Our results indicate that VMAT-S provides better sparing of hearing apparatus in locoregionally advanced NPC. ADVANCES IN KNOWLEDGE: VMAT-S can improve the middle ear, vestibule and cochlea sparing in patients with locoregionally advanced NPC.[Abstract] [Full Text] [Related] [New Search]