These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Effective Bronchoscopic Lung Volume Reduction Accelerates Exercise Oxygen Uptake Kinetics in Emphysema. Author: Faisal A, Zoumot Z, Shah PL, Neder JA, Polkey MI, Hopkinson NS. Journal: Chest; 2016 Feb; 149(2):435-446. PubMed ID: 26111199. Abstract: BACKGROUND: The impact of bronchoscopic lung volume reduction (BLVR) on physiologic responses to exercise in patients with advanced emphysema remains incompletely understood. We hypothesized that effective BLVR (e-BLVR), defined as a reduction in residual volume > 350 mL, would improve cardiovascular responses to exercise and accelerate oxygen uptake (Vo₂) kinetics. METHODS: Thirty-one patients (FEV1, 36% ± 9% predicted; residual volume, 219% ± 57% predicted) underwent a constant intensity exercise test at 70% peak work rate to the limit of tolerance before and after treatment bronchoscopy (n = 24) or sham bronchoscopy (n = 7). Physiologic responses in patients who had e-BLVR (n = 16) were compared with control subjects (ineffective BLVR or sham bronchoscopy; n = 15). RESULTS: e-BLVR reduced residual volume (-1.1 ± 0.5 L, P = .001), improved lung diffusing capacity by 12% ± 13% (P = .001), and increased exercise tolerance by 181 ± 214 s (P = .004). Vo₂ kinetics were accelerated in the e-BLVR group but remained unchanged in control subjects (Δ mean response time, -20% ± 29% vs 1% ± 25%, P = .04). Acceleration of Vo₂ kinetics was associated with reductions in heart rate and oxygen pulse response half-times by 8% (84 ± 14 to 76 ± 15 s, P = .04) and 20% (49 ± 16 to 34 ± 16 s, P = .01), respectively. There were also increases in heart rate and oxygen pulse amplitudes during the cardiodynamic phase post e-BLVR. Faster Vo₂ kinetics in the e-BLVR group were significantly correlated with reductions in residual volume (r = 0.66, P = .005) and improvements in inspiratory reserve volume (r = 0.56, P = .024) and exercise tolerance (r = 0.63, P = .008). CONCLUSIONS: Lung deflation induced by e-BLVR accelerated exercise Vo₂ kinetics in patients with emphysema. This beneficial effect appears to be related mechanistically to an enhanced cardiovascular response to exercise, which may contribute to improved functional capacity.[Abstract] [Full Text] [Related] [New Search]