These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Highly selective and sensitive nanoprobes for cyanide based on gold nanoclusters with red fluorescence emission.
    Author: Zhang G, Qiao Y, Xu T, Zhang C, Zhang Y, Shi L, Shuang S, Dong C.
    Journal: Nanoscale; 2015 Aug 07; 7(29):12666-72. PubMed ID: 26148527.
    Abstract:
    We report a novel and environmentally friendly fluorescent probe for detecting the cyanide ion (CN(-)) using L-amino acid oxidase (LAAOx)-protected Au nanoclusters (LAAOx@AuNCs) with red emission. The fluorescence-based sensing behaviour of LAAOx@AuNCs towards anions was investigated in buffered aqueous media. Among the anions studied, CN(-) was found to effectively quench the fluorescence emission of AuNCs based on CN(-) induced Au core decomposition. Excellent sensitivity and selectivity toward the detection of CN(-) in aqueous solution were observed. The CN(-) detection limit was determined to be approximately 180 nM, which is 15 times lower than the maximum level (2700 nM) of CN(-) in drinking water permitted by the World Health Organization (WHO). A linear relationship between the fluorescence intensity and CN(-) concentration was observed in two ranges of CN(-) concentration, including 3.2 × 10(-6) to 3.4 × 10(-5) mol L(-1) and 3.81 × 10(-5) to 1.04 × 10(-4) mol L(-1). The high sensitivity and selectivity to CN(-) among the 17 types of anions make the AuNCs good candidates for use in fluorescent nanoprobes of CN(-).
    [Abstract] [Full Text] [Related] [New Search]