These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Prosthesis-Specific Predictors of Paravalvular Regurgitation after Transcatheter Aortic Valve Replacement: Impact of Calcification and Sizing on Balloon-Expandable versus Self-Expandable Transcatheter Heart Valves. Author: Stähli BE, Nguyen-Kim TD, Gebhard C, Erhart L, Frauenfelder T, Tanner FC, Falk V, Landmesser U, Nietlispach F, Lüscher TF, Maier W, Binder RK. Journal: J Heart Valve Dis; 2015 Jan; 24(1):10-21. PubMed ID: 26182615. Abstract: BACKGROUND AND AIM OF THE STUDY: The study aim was to investigate prosthesis-specific predictors for paravalvular aortic regurgitation (PAR) in self-expandable versus balloon-expandable transcatheter heart valves (THVs). PAR is frequently observed after transcatheter aortic valve replacement (TAVR). As self-expandable and balloon-expandable THVs engage differently with the native aortic valve structures, factors that impact PAR may differ between the prosthesis types. METHODS: A total of 137 TAVR patients who underwent pre-procedural multidetector computed tomography and post-procedural transthoracic echocardiography were studied. Predictors for PAR, including annulus area oversizing and aortic valve calcification mass and volume, were analyzed in a multivariate model. RESULTS: The Medtronic CoreValve (MCV) prosthesis was utilized in 68 patients (50%), and the Edwards SAPIEN (ES) prosthesis in 69 (50%). More than mild PAR was observed in 43 patients (32%). Among MCV patients, aortic valve calcification volume and mass were higher in those with more than mild PAR than in those with none or mild PAR (p = 0.04, p = 0.03, respectively). Among ES patients, the annulus area and perimeter oversizing were lower in those with more than mild PAR compared to those with no or mild PAR (p = 0.001). By univariate and multivariate logistic regression analysis, aortic valve calcification mass was the only independent predictor for PAR in MCV patients (p = 0.02), whereas in ES patients it was THV undersizing (p = 0.002), irrespective of the calcific burden. CONCLUSION: For self-expandable THVs, aortic valve calcification mass was the strongest predictor of PAR, whereas for balloon-expandable THVs it was prosthesis undersizing. Hence, in patients evaluated for TAVR these parameters should guide the selection of prosthesis type.[Abstract] [Full Text] [Related] [New Search]