These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Computer simulation of arcuate and radial incisions involving the corneoscleral limbus.
    Author: Hanna KD, Jouve FE, Waring GO, Ciarlet PG.
    Journal: Eye (Lond); 1989; 3 ( Pt 2)():227-39. PubMed ID: 2620750.
    Abstract:
    We have created a computer model of the eye that improves upon previous models with two assumptions: (1) the cornea is considered anisotropic, and (2) the strain tensor is non-linear for large displacements. Values used include those for Young's modulus, Poisson's ratio, and three coefficients of anisotropia. A finite element computer program was used to stimulate the behaviour of the eye. Four simulations were done: (1) a full thickness arcuate limbal cataract incision, (2) a partial thickness arcuate corneal relaxing incision, (3) a partial thickness radial incision extending across the limbus, (4) a partial thickness radial incision confined to the cornea. A full thickness corneal arcuate incision for cataract induced more change in corneal shape than a limbal incision. However, the gaping is more important in the limbal incision. Partial thickness arcuate corneal relaxing incisions were found to be more effective with a clear zone 3-5 mm in diameter. Radial incision simulation demonstrated little enhancement of the effect of the incisions when across the limbus.
    [Abstract] [Full Text] [Related] [New Search]