These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Iterative reconstruction in single source dual-energy CT pulmonary angiography: Is it sufficient to achieve a radiation dose as low as state-of-the-art single-energy CTPA? Author: Ohana M, Labani A, Jeung MY, El Ghannudi S, Gaertner S, Roy C. Journal: Eur J Radiol; 2015 Nov; 84(11):2314-20. PubMed ID: 26210093. Abstract: OBJECTIVE: Dual-energy (DE) brings numerous significant improvements in pulmonary CT angiography (CTPA), but is associated with a 15-50% increase in radiation dose that prevents its widespread use. We hypothesize that thanks to iterative reconstruction (IR), single source DE-CTPA acquired at the same radiation dose that a single-energy examination will maintain an equivalent quantitative and qualitative image quality, allowing a more extensive use of the DE technique in the clinical routine. MATERIAL AND METHODS: Fifty patients (58% men, mean age 64.8yo ± 16.2, mean BMI 25.6 ± 4.5) were prospectively included and underwent single source DE-CTPA with acquisition parameters (275 mA fixed tube current, 50% IR) tweaked to target a radiation dose similar to a 100 kV single-energy CTPA (SE-CTPA), i.e., a DLP of 260 mGy cm. Thirty patients (47% men, 64.4yo ± 18.6, BMI 26.2 ± 4.6) from a previous prospective study on DE-CTPA (375 mA fixed tube current, reconstruction with filtered-back projection) were used as the reference group. Thirty-five consecutive patients (57% men, 65.8yo ± 15.5, BMI 25.7 ± 4.4) who underwent SE-CTPA on the same scanner (automated tube current modulation, 50% IR) served as a comparison. Subjective image quality was scored by two radiologists using a 5-level scale and compared with a Kruskal-Wallis nonparametric test. Density measurements on the 65 keV monochromatic reconstructions were used to calculate signal-to-noise (SNR) and contrast-to-noise (CNR) ratios that were compared using a Student's t test. Correlations between image quality, SNR, CNR and BMI were sought using a Pearson's test. p<0.05 was considered significant. RESULTS: All examinations were of diagnostic quality (score ≥ 3). In comparison with the reference DE-CTPA and the SE-CTPA protocols, the DE-IR group exhibited a non-inferior image quality (p=0.95 and p=0.21, respectively) and a significantly lower mean image noise (p<0.01 and p=0.01) thus slightly improving the SNR (p=0.09 and p=0.47) and the CNR (p=0.12 and p=0.51). There was a strong negative relationship between BMI and SNR/CNR (ρ=-0.59 and -0.55 respectively), but only a moderate negative relationship between BMI and image quality (ρ=-0.27). CONCLUSION: With iterative reconstruction, objective and subjective image quality of single source DE-CTPA are preserved even though the radiation dose is lowered to that of a single-energy examination, overcoming a major limitation of the DE technique and allowing a widespread use in the clinical routine.[Abstract] [Full Text] [Related] [New Search]