Title: Development of a cobinamide-based end-of-service-life indicator for detection of hydrogen cyanide gas. Author: Greenawald LA, Snyder JL, Fry NL, Sailor MJ, Boss GR, Finklea HO, Bell S. Journal: Sens Actuators B Chem; 2015 Dec 31; 221():379-385. PubMed ID: 26213448. Abstract: We describe an inexpensive paper-based sensor for rapid detection of low concentrations (ppm) of hydrogen cyanide gas. A piece of filter paper pre-spotted with a dilute monocyanocobinamide [CN(H2O)Cbi] solution was placed on the end of a bifurcated optical fiber and the reflectance spectrum of the CN(H2O)Cbi was monitored during exposure to 1.0-10.0 ppm hydrogen cyanide gas. Formation of dicyanocobinamide yielded a peak at 583 nm with a simultaneous decrease in reflectance from 450-500 nm. Spectral changes were monitored as a function of time at several relative humidity values: 25, 50, and 85% relative humidity. With either cellulose or glass fiber papers, spectral changes occurred within 10 s of exposure to 5.0 ppm hydrogen cyanide gas (NIOSH recommended short-term exposure limit). We conclude that this sensor could provide a real-time end-of-service-life alert to a respirator user.[Abstract] [Full Text] [Related] [New Search]