These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: The Different Sensitive Behaviors of a Hydrogen-Bond Acidic Polymer-Coated SAW Sensor for Chemical Warfare Agents and Their Simulants.
    Author: Long Y, Wang Y, Du X, Cheng L, Wu P, Jiang Y.
    Journal: Sensors (Basel); 2015 Jul 28; 15(8):18302-14. PubMed ID: 26225975.
    Abstract:
    A linear hydrogen-bond acidic (HBA) linear functionalized polymer (PLF), was deposited onto a bare surface acoustic wave (SAW) device to fabricate a chemical sensor. Real-time responses of the sensor to a series of compounds including sarin (GB), dimethyl methylphosphonate (DMMP), mustard gas (HD), chloroethyl ethyl sulphide (2-CEES), 1,5-dichloropentane (DCP) and some organic solvents were studied. The results show that the sensor is highly sensitive to GB and DMMP, and has low sensitivity to HD and DCP, as expected. However, the sensor possesses an unexpected high sensitivity toward 2-CEES. This good sensing performance can't be solely or mainly attributed to the dipole-dipole interaction since the sensor is not sensitive to some high polarity solvents. We believe the lone pair electrons around the sulphur atom of 2-CEES provide an electron-rich site, which facilitates the formation of hydrogen bonding between PLF and 2-CEES. On the contrary, the electron cloud on the sulphur atom of the HD molecule is offset or depleted by its two neighbouring strong electron-withdrawing groups, hence, hydrogen bonding can hardly be formed.
    [Abstract] [Full Text] [Related] [New Search]