  • Title: High-Throughput Arginylation Assay in Microplate Format.
    Author: Saha S, Wang J, Kashina AS.
    Journal: Methods Mol Biol; 2015; 1337():79-82. PubMed ID: 26285884.
    Abstract:
    Here we describe the biochemical assay for ATE1-mediated arginylation in microplate format, which can be applied to high-throughput screens for identification of small-molecule inhibitors and activators of ATE1, high-volume analysis of ATE1 substrates, and other similar applications. Originally, we have applied this screen to a library of 3280 compounds and identified two compounds which specifically affect ATE1-regulated processes in vitro and in vivo. The assay is based on in vitro ATE1-mediated arginylation of beta-actin's N-terminal peptide, but it can also be applied using other ATE1 substrates.