These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: A highly sensitive and selective fluorescent probe for trivalent aluminum ion based on rhodamine derivative in living cells.
    Author: Tang JL, Li CY, Li YF, Lu X, Qi HR.
    Journal: Anal Chim Acta; 2015 Aug 12; 888():155-61. PubMed ID: 26320971.
    Abstract:
    A rhodamine spirolactam derivative (1) is developed as a colormetric and fluorescent probe for trivalent aluminum ions (Al(3+)). It exhibits a highly sensitive "turn-on" fluorescent response toward Al(3+) with a 70-fold fluorescence intensity enhancement under 2 equiv. of Al(3+) added. The probe can be applied to the quantification of Al(3+) with a linear range covering from 5.0 × 10(-7) to 2.0 × 10(-5) M and a detection limit of 4.0 × 10(-8) M. Most importantly, the fluorescence changes of the probe are remarkably specific for Al(3+) in the presence of other metal ions, which meet the selective requirements for practical application. Moreover, the experiment results show that the response behavior of 1 towards Al(3+) is pH independent in neutral condition (pH 6.0-8.0) and the response of the probe is fast (response time less than 3 min). In addition, the proposed probe has been used to detect Al(3+) in water samples and image Al(3+) in living cells with satisfying results.
    [Abstract] [Full Text] [Related] [New Search]