These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Comparison between drug-coated balloon angioplasty and second-generation drug-eluting stent placement for the treatment of in-stent restenosis after drug-eluting stent implantation. Author: Kang IS, Shehata I, Shin DH, Kim JS, Kim BK, Ko YG, Choi D, Jang Y, Hong MK. Journal: Heart Vessels; 2016 Sep; 31(9):1405-11. PubMed ID: 26337620. Abstract: Even though drug-coated balloon (DCB) angioplasty has emerged as a treatment option for drug-eluting stent in-stent restenosis (DES-ISR), the most effective treatment strategy for DES-ISR is still under debate. Therefore, we compared long-term clinical outcomes following DCB treatment of DES-ISR with those following 2nd-generation drug-eluting stent (DES) treatment. We identified 248 DES-ISR lesions in 238 patients that were treated with either 2nd-generation DES implantation (n = 56) or DCB angioplasty (n = 192). We compared the incidences of major adverse cardiac events (MACEs) in the two groups during the 2-year period following treatment. MACE was defined as cardiac death, non-fatal myocardial infarction, or target-vessel revascularization. The percentage of patients with diabetes and the mean age of patients in the DCB group were greater than in the DES group. The DCB group also had a smaller reference vessel diameter. The DES group had a larger post-intervention minimal luminal diameter. We found no significant difference in the MACE rate between the two groups during the 2 years following treatment (11.0 % in the DCB group vs. 8.9 % in the DES group, p = 0.660). Reference segment diameter was the only independent predictive factor for MACE in the post-treatment period (hazard ratio 0.35, 95 % confidence interval: 0.15-0.82, p = 0.016). Clinical efficacy of DCB angioplasty for treatment of DES-ISR was comparable to that of 2nd-generation DES implantation as measured by the rate of MACEs in the two groups. Reference segment diameter was the only statistically significant independent predictor for MACE in the 2-year period following treatment.[Abstract] [Full Text] [Related] [New Search]