These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: [Pesticide determination in water after separation on reverse-phase minicolumns].
    Author: Molto JC, Font G, Farre R, Mañes J.
    Journal: Rev Sanid Hig Publica (Madr); 1989; 63(7-8):31-7. PubMed ID: 2635371.
    Abstract:
    The lindane, methoxichlor, parathion and methylparathion content of water is measured in a gas-chromatography fitted with a capture electron detector. Prior extraction and concentration are done by using Sep-Pak C18 cartridges with ethyl acetate as eluent, which is offers certain advantages over hexane and methanol. With solutions of 0.5 ppb recovery values of 102.7% (lindane), 85% (methoxychlor), 94.7% (parathion) and 93.1% (methylparathion) are obtained. The method proposed is less time-consuming and less expensive than the usual consisting of extraction with dichloromethane: hexane (15:75 v/V) and concentration in a Kuderna-Danish.
    [Abstract] [Full Text] [Related] [New Search]