  • Title: Scanning electron microscope study of scalers.
    Author: Antonini CJ, Brady JM, Levin MP, Garcia WL.
    Journal: J Periodontol; 1977 Jan; 48(1):45-8. PubMed ID: 264541.
    Abstract:
    Scanning electron microscopy was used to examine factory-sharpened, dulled, and resharpened scalers. The following observations were made: 1. The factory sharpened scalers exhibited metallic extensions from the lateral surface (wire edges). 2. The machine-resharpened instruments resulted in nonfunctional wire edges from the facial surface. Honing produced an exact meeting of facial and lateral surfaces. 3. Hand sharpening, using an Arkansas stone (grit 500) against the lateral surface away from the cutting edge, effected an exact meeting of the facial and lateral surfaces and no evidence of wire edges. 4. From this study an optimum cutting edge for a scaler is characterized as having a smooth, contiguous meeting of the facial and lateral surfaces free of wire edges. If a wire edge is present, it should be functional.