These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Ultra high performance liquid chromatography tandem mass spectrometric detection of glucuronides resistant to enzymatic hydrolysis: Implications to doping control analysis. Author: Kotronoulas A, Marcos J, Segura J, Ventura R, Joglar J, Pozo OJ. Journal: Anal Chim Acta; 2015 Oct 01; 895():35-44. PubMed ID: 26454457. Abstract: Controversial results have been reported in the literature regarding the behavior of two testosterone (T) metabolites (3α-glucuronide-6β-hydroxyandrosterone and 3α-glucuronide-6β-hydroxyetiocholanolone) excreted after T administration. Due to their potential as biomarkers of T misuse, a UHPLC-MS/MS method for the direct quantification of these glucuronides was developed and validated. In addition, the main phase II metabolites of T that compose the steroid profile used for doping control purposes (glucuronides of T, epitestosterone, androsterone and etiocholanolone) were included. The method was found to be linear and with suitable LODs and LOQs for all metabolites. The average accuracies were between 86% and 120%, the RSDs for the intra- and inter-day precision were below 15% and 25% respectively. The method showed low matrix effect. Samples obtained before and after the administration of T were analyzed by both the developed UHPLC-MS/MS method and the GC-MS/MS method currently used by anti-doping laboratories. Relevant disagreements between the results obtained for 3α-glucuronide-6β-hydroxyandrosterone and 3α-glucuronide-6β-hydroxyetiocholanolone quantitation were observed. These markers seemed to be more suitable for the screening of T misuse when detected by UHPLC-MS/MS. These discrepancies were further investigated in 50 urine samples from healthy volunteers. The two methods gave highly correlated results for all metabolites that are currently included in the athlete's steroid profile confirming the reliability of the UHPLC-MS/MS method. However, the quantification of 3α-glucuronide-6β-hydroxyandrosterone and 3α-glucuronide-6β-hydroxyetiocholanolone, was only possible by using the UHPLC-MS/MS method since three interfering compounds were observed when performing the GC-MS/MS analysis with the most intense ion transitions. These results confirm the potential of the resistant glucuronides as biomarkers of T misuse. Additionally, they suggest that previously reported reference ranges for these metabolites should be reevaluated.[Abstract] [Full Text] [Related] [New Search]