These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: [Ultrabraid SUTURE WITH FOOTPRINT RIVET FOR ANTERIOR CRUCIATE LIGAMENT TIBIAL EMINENCE AVULSION FRACTURE IN ADOLESCENTS UNDER ARTHROSCOPY].
    Author: Liang J, Zheng J, Ll Q, Zhong S, Chen M.
    Journal: Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2015 Jun; 29(6):721-4. PubMed ID: 26466475.
    Abstract:
    OBJECTIVE: To investigate the clinical effects of the Ultrabraid suture with FOOTPRINT rivet by arthroscopic technique for the treatment of anterior cruciate ligament (ACL) tibial eminence avulsion fracture. METHODS: Between May 2011 and December 2013, 19 adolescent patients with ACL tibial eminence avulsion fracture were treated with arthroscopic reduction and fixation by Ultrabraid sutures with FOOTPRINT rivet. There were 13 males and 6 females with an average age of 15.8 years (range, 8-18 years). The left knees were involved in 10 cases and the right knees in 9 cases. The injury causes included traffic accident injury in 8 cases, sport injury in 6 cases, and sprain injury in 5 cases. Three patients had old fractures, and the others had fresh fractures. The results of Lachman test and anterior drawer test were both positive. The International Knee Documentation Committee (IKDC) subject score was 54.2 ± 4.0. Based on Meyers-McKeever classification, there were 3 cases of type II, 10 cases of type III, and 6 cases of type IV. RESULTS: The operation time was 50-60 minutes (mean, 55.2 minutes). X-ray film showed satisfactory fracture reduction at 1 day after operation. Primary healing of incision was obtained with no infection. Eighteen patients were followed up for 1-3 years (mean, 1.7 years). All fractures healed with smooth joint surface on the X-ray film at 3 months after operation. The results of Lachman test and anterior drawer test were both negative in 17 cases, and the results was negative for anterior drawer test and was weakly positive for Lachman test in 1 case. The IKDC subject score was significantly improved to 96.1 ± 2.1 at last follow-up (t = 34.600, P = 0.000). CONCLUSION: It could achieve early restoration of knee joint function to treat the ACL tibial eminence avulsion fracture by arthroscopic technique of the Ultrabraid suture with FOOTPRINT rivet because of satisfactory reduction, reliable fixation, small wound, and early rehabilitation.
    [Abstract] [Full Text] [Related] [New Search]