These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: [Determination of n-pentanol in workplace air by solvent desorption gas chromatography].
    Author: Li T, Liu F, Lin Y, Xie Y, Yan H.
    Journal: Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi; 2015 Apr; 33(4):304-6. PubMed ID: 26506787.
    Abstract:
    OBJECTIVE: To develop a solvent desorption gas chromatographic method for determination of n-pentanol in the workplace air. METHODS: n-Pentanol in the workplace air was collected with activated carbon tubes, desorbed with 2% 2-propanol in carbon disulfide, separated with a nitroterephthalic acid-modified FFAP capillary column, and detected with flame ionization detector. RESULTS: The limit of detection was 0.2 mg/L; the lower limit of quantification was 0.6 mg/L; the linear range was 0.6-4072.0 mg/L. The minimum detectable mass concentration was 0.2 mg/m3 for 1.5 L of air sample. This method was highly repeatable. The relative standard deviations were 2.3%-5.4%. The average desorption efficiencies were 86.9%-94.2%. The absorption efficiencies were 100%. The breakthrough volume was above 8.0 mg in 100-mg activated carbon. The samples in activated carbon tubes could be stored for at least 14 days at room temperature. CONCLUSION: The method is feasible for determination of n-pentanol in the workplace air.
    [Abstract] [Full Text] [Related] [New Search]