  • Title: A retrospective analysis on the utility and complications of upper arm ports in 433 cases at a single institute.
    Author: Mori Y, Nagayama S, Kawamura J, Hasegawa S, Tanaka E, Okabe H, Takeuchi M, Sonobe M, Matsumoto S, Kanai M, Muto M, Chiba T, Sakai Y.
    Journal: Int J Clin Oncol; 2016 Jun; 21(3):474-82. PubMed ID: 26507141.
    Abstract:
    BACKGROUND: We have employed upper arm central venous ports (UACVPs) since 2006 for long-term intravenous chemotherapy (CTx) or fluid supplementation. We evaluated the long-term availability of CVPs implanted in the upper arm to determine whether UACVPs could be one of the treatment options besides chest CVPs in terms of CVP-related complications. METHODS: We reviewed the medical records of all patients who underwent subcutaneous implantation of UACVPs at Kyoto University Hospital from 1 April, 2006 to 30 June, 2009. We assessed the indwelling duration of the UACVPs and the incidences of early and late UACVP-related complications. RESULTS: A total of 433 patients underwent subcutaneous implantation of UACVPs during this time period. The cumulative follow-up period was 251,538 catheter days, and the median duration of UACVP indwelling was 439.0 days (1-2, 24). There was no UACVP-related mortality throughout the study period. A total of 83 UACVP-related complications occurred (19.2 %), including 43 cases of infection (9.9 %, 0.17/1000 catheter days), ten cases of catheter-related thrombosis (2.3 %, 0.040/1000 catheter days), ten cases of occlusion (2.3 %, 0.040/1000 catheter days), nine cases of catheter dislocation (2.0 %, 0.036/1000 catheter days), five cases of port leakage (1.2 %, 0.019/1000 catheter days), four cases of skin dehiscence (0.9 %, 0.015/1000 catheter days) and two cases of port chamber twist (0.5 %, 0.008/1000 catheter days). The removal-free one-year port availability was estimated at 87.8 %. CONCLUSIONS: UACVPs were of long-term utility, with complication rates comparable to those of chest CVPs previously reported.
    [Abstract] [Full Text] [Related] [New Search]