  • Title: The impact of image resolution on computation of fractional flow reserve: coronary computed tomography angiography versus 3-dimensional quantitative coronary angiography.
    Author: Liu L, Yang W, Nagahara Y, Li Y, Lamooki SR, Muramatsu T, Kitslaar P, Sarai M, Ozaki Y, Barlis P, Yan F, Reiber JH, Tu S.
    Journal: Int J Cardiovasc Imaging; 2016 Mar; 32(3):513-23. PubMed ID: 26507326.
    Abstract:
    Calculation of fractional flow reserve (FFR) based on computational fluid dynamics (CFD) requires reconstruction of patient-specific coronary geometry and estimation of hyperemic flow rate. Coronary computed tomography angiography (CCTA) and invasive coronary angiography (ICA) are two dominating imaging modalities used for the geometrical reconstruction. Our aim was to investigate the impact of image resolution as inherently associated with these two imaging modalities on geometrical reconstruction and subsequent FFR calculation. Patients with mild or intermediate coronary stenoses who underwent both CCTA and ICA were included. CCTA images were acquired either by 320-row area detector CT or by 128-slice dual-source CT. Two geometrical models were reconstructed separately from CCTA and ICA, from which FFRCTA and FFRQCA were subsequently calculated using CFD simulations, applying the same hyperemic flow rate derived from the ICA images at the inlet boundaries. A total of 57 vessels in 41 patients were analyzed. Average diameter stenosis was 43.4 ± 10.8 % by 3D QCA. Reasonably good correlation between FFRCTA and FFRQCA was observed (r = 0.71, p < 0.001). The difference between FFRCTA and FFRQCA was correlated with the deviation between minimal lumen areas by CCTA and by ICA (ρ = 0.34, p = 0.01), but not with plaque volume (ρ = -0.09, p = 0.51) or calcified plaque volume (ρ = 0.01, p = 0.95). Applying the cutoff value of ≤0.8 to both FFRCTA and FFRQCA, the agreement between FFRCTA and FFRQCA in discriminating functional significant stenoses was moderate (kappa 0.47, p < 0.001). Disagreement was found in 10 (17.5 %) vessels. Acceptable correlation between FFRCTA and FFRQCA was observed, while their agreement in distinguishing functional significant stenosis was moderate. Our results suggest that image resolution has a significant impact on FFR computation.
    [Abstract] [Full Text] [Related] [New Search]