These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Externalized Guidewires to Facilitate Fenestrated Endograft Deployment in the Aortic Arch. Author: Joseph G, Premkumar P, Thomson V, Varghese M, Selvaraj D, Sahajanandan R. Journal: J Endovasc Ther; 2016 Feb; 23(1):160-71. PubMed ID: 26511895. Abstract: PURPOSE: To describe a precannulated fenestrated endograft system utilizing externalized guidewires to facilitate aortic arch endovascular repair and to report its use in 2 patients with challenging anatomy. TECHNIQUE: For distal arch repair, a fenestration for the left subclavian artery (LSA) is made onsite in a standard thoracic endograft tailored to the patient anatomy; it is precannulated with a nitinol guidewire (NGw), which is passed from the femoral artery and externalized from the left brachial artery prior to endograft delivery system introduction over a parallel stiff guidewire. Steps are then taken to remove guidewire intertwining, prevent NGw wrapping around the delivery system, and orient the LSA fenestration superiorly when the delivery system moves into the arch. Gentle traction on the ends of the NGw during endograft deployment facilitates proper fenestration alignment. A covered stent is deployed in the LSA fenestration. The technique is illustrated in a patient with congenital coarctation of the aorta and descending aortic aneurysm. For total arch repair, endograft fenestrations are made for all 3 arch branches; the left common carotid artery (LCCA) and LSA fenestrations are each cannulated with NGws, which travel together from the femoral artery, pass through a LSA snare loop, and are exteriorized from the LCCA. After endograft deployment, the innominate artery fenestration is separately cannulated using right brachial access. Placement of a parallel externalized hydrophilic guidewire passing through the LCCA fenestration (but not the LSA snare loop) and removal of the LCCA fenestration NGw allows exteriorization of the LSA fenestration NGw from the left brachial artery by pulling the LSA snare. Covered stents are deployed in all 3 fenestrations. The technique is presented in a patient with type B aortic dissection. CONCLUSION: Use of the precannulated fenestrated endograft system described is feasible and has the potential to make aortic arch endovascular repair simpler, more reliable, and safer.[Abstract] [Full Text] [Related] [New Search]