These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Randomized Pilot Trial of Two Modified Endotracheal Tubes To Prevent Ventilator-associated Pneumonia. Author: Deem S, Yanez D, Sissons-Ross L, Broeckel JA, Daniel S, Treggiari M. Journal: Ann Am Thorac Soc; 2016 Jan; 13(1):72-80. PubMed ID: 26523433. Abstract: RATIONALE: Ventilator-associated pneumonia (VAP) is a prevalent and costly nosocomial infection related to instrumentation of the airway with an endotracheal tube (ETT), enabling microaspiration of contaminated secretions. Modification of the ETT design to reduce microaspiration and/or biofilm formation may play an important role in VAP prevention. However, there is insufficient evidence to provide strong recommendations regarding the use of modified ETT and unaddressed safety concerns. OBJECTIVES: We performed a pilot randomized controlled trial comparing two modified ETTs designed specifically to prevent VAP, with the standard ETT, to test the feasibility of and inform planning for a large, pivotal, randomized trial. METHODS: This study was conducted with institutional review board approval under exception from informed consent. We randomized in a blinded fashion patients undergoing emergency endotracheal intubation both out of and in hospital to receive one of three different ETT types: (1) a polyurethane-cuffed tube (PUC-ETT), (2) a polyurethane-cuffed tube equipped with a port for continuous aspiration of subglottic secretions (PUC-CASS-ETT), or a (3) standard polyvinylchloride-cuffed tube (PVC-ETT). In addition to investigating feasibility and safety, the study coprimary end points were tracheal bacterial colonization reaching a cfu count >10(6) cfu per milliliter and the incidence of invasively diagnosed VAP. MEASUREMENTS AND MAIN RESULTS: A total of 102 subjects were randomized and met the eligibility criteria. Randomization procedures performed well and integrity of blinding at randomization was maintained. The majority of intubations occurred in the hospital setting (n = 77), and the remainder occurred out of hospital (n = 25). Compared with the PVC-ETT, there were no significant differences in tracheal colonization for PUC-ETT (odds ratio [OR], 0.98; 95% confidence interval [CI], 0.31-3.09) or for PUC-CASS-ETT (OR, 1.26; 95% CI, 0.42-3.76). There were no differences in the risk of invasively diagnosed VAP (OR, 1.14; 95% CI, 0.21-6.08 for PUC-ETT; OR, 1.47; 95% CI, 0.30-7.10 for PUC-CASS-ETT), or of clinically diagnosed VAP by either clinical signs or chest radiograph criteria. We did not observe unexpected or serious adverse events related to the devices. CONCLUSIONS: A randomized trial of ETTs inserted during emergency intubation for the prevention of VAP is feasible and did not appear to carry heightened safety concerns. These preliminary data did not suggest different patterns of tracheal colonization or occurrence of VAP among the study groups. Clinical trial registered with www.clinicaltrials.gov (NCT01744483).[Abstract] [Full Text] [Related] [New Search]