Title: The feasibility of using 'bring your own device' (BYOD) technology for electronic data capture in multicentre medical audit and research. Author: Faulds MC, Bauchmuller K, Miller D, Rosser JH, Shuker K, Wrench I, Wilson P, Mills GH, South Yorkshire Hospitals Audit and Research Collaboration (SHARC). Journal: Anaesthesia; 2016 Jan; 71(1):58-66. PubMed ID: 26526934. Abstract: Large-scale audit and research projects demand robust, efficient systems for accurate data collection, handling and analysis. We utilised a multiplatform 'bring your own device' (BYOD) electronic data collection app to capture observational audit data on theatre efficiency across seven hospital Trusts in South Yorkshire in June-August 2013. None of the participating hospitals had a dedicated information governance policy for bring your own device. Data were collected by 17 investigators for 392 individual theatre lists, capturing 14,148 individual data points, 12, 852 (91%) of which were transmitted to a central database on the day of collection without any loss of data. BYOD technology enabled accurate collection of a large volume of secure data across multiple NHS organisations over a short period of time. Bring your own device technology provides a method for collecting real-time audit, research and quality improvement data within healthcare systems without compromising patient data protection.[Abstract] [Full Text] [Related] [New Search]