These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Pursed-lips breathing reduces dynamic hyperinflation induced by activities of daily living test in patients with chronic obstructive pulmonary disease: A randomized cross-over study. Author: de Araujo CL, Karloh M, Dos Reis CM, Palú M, Mayer AF. Journal: J Rehabil Med; 2015 Nov; 47(10):957-62. PubMed ID: 26538411. Abstract: BACKGROUND: Dynamic hyperinflation leads to dyspnoea and consequent limitations in functional capacity in chronic obstructive pulmonary disease. It has been shown that the response to pursed-lips breathing in terms of dynamic hyperinflation and lower-limb exercise capacity is variable, and its effects on activities of daily living are unknown. This study aimed to evaluate the effect of pursed-lips breathing on dynamic hyperinflation and functional capacity in patients with chronic obstructive pulmonary disease in a lower-limb exercise test and in a multiple-task activities of daily living test. DESIGN: Randomized cross-over study. PATIENTS: Twenty-five patients with chronic obstructive pulmonary disease (16 men, mean age 64 ± 7 years, forced expiratory volume in 1 s (FEV1) = 41.7 ± 14.7% predicted). METHODS: Patients randomly performed two 6-min walk tests (6MWT) with and without pursed-lips breathing (6MWT(PLB) and 6MWT(Non-PLB)) and two Glittre-ADL tests with and without pursed-lips breathing (TGlittre(PLB) and TGlittre(Non-PLB)). Inspiratory capacity was assessed at baseline and immediately after the tests. RESULTS: The 6MWT(Non-PLB) and TGlittre(Non-PLB) induced similar magnitude dynamic hyperinflation (0.22 ± 0.24 l and 0.31 ± 0.23 l, respectively; p > 0.05). Pursed-lips breathing did not improve dynamic hyperinflation induced by the 6MWT (0.24 ± 0.20 and 0.22 ± 0.24 l, respectively, with and without pursed-lips breathing; p > 0.05). Dynamic hyperinflation in the TGlittre(PLB) was significantly lower than in the TGlittre(Non-PLB) (0.19 ± 0.20 l and 0.31 ± 0.23 l, respectively; p = 0.02). Pursed-lips breathing did not improve 6MWT or TGlittre performance. CONCLUSION: Pursed-lips breathing reduced dynamic hyperinflation in the TGlittre, but not in the 6MWT. However, pursed-lips breathing did not improve functional capacity.[Abstract] [Full Text] [Related] [New Search]