These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Treatment of Distal Anterior Circulation Aneurysms With the Pipeline Embolization Device: A US Multicenter Experience. Author: Lin N, Lanzino G, Lopes DK, Arthur AS, Ogilvy CS, Ecker RD, Dumont TM, Turner RD, Gooch MR, Boulos AS, Kan P, Snyder KV, Levy EI, Siddiqui AH. Journal: Neurosurgery; 2016 Jul; 79(1):14-22. PubMed ID: 26579967. Abstract: BACKGROUND: Utilization of the Pipeline embolization device (PED) to treat distal carotid circulation aneurysms has not been well studied. OBJECTIVE: To report the collective experience of using PED to treat distal anterior circulation aneurysms. METHODS: We retrospectively reviewed clinical and radiographic records of all patients who underwent Pipeline embolization of distal anterior circulation aneurysms at 10 US neurosurgical centers between 2011 and 2013. RESULTS: Twenty-eight patients (mean age 51.7 years; 18 women) with 28 aneurysms were included in the analyses. Fifteen aneurysms were fusiform, 5 dissecting, and 8 saccular. Average aneurysm size was 12.3 mm; 7 were giant. Twenty aneurysms were located along the middle cerebral artery, 6 along the anterior cerebral artery, and 2 along the anterior communicating artery. PED deployment was successful in 27 patients, with coils utilized in 6 cases. Clinical follow-up was available for an average of 10.7 months (range 3-26). Twenty-seven patients had follow-up neurovascular imaging: 21 aneurysms had complete occlusion, 4 had residual neck filling, and 2 had residual dome filling. Periprocedural complications (<30 days) occurred in 3 patients (10.7%), including 1 case of device failure resulting in stroke. Outcomes were good (modified Rankin Scale score 0 to 2) in 27 patients (96.4%) and fair (modified Rankin Scale 3) in 1. CONCLUSION: PED can be utilized in the treatment of distal anterior circulation aneurysms with difficult anatomy for conventional surgical or endovascular techniques. Larger-scale studies with long-term follow-up are needed to further elucidate the durability of PED treatment and its effect on perforator-rich vascular segments. ABBREVIATIONS: ACA, anterior cerebral arteryAcomA, anterior communicating arteryDSA, digital subtraction angiographyMCA, middle cerebral arterymRS, modified Rankin scalePED, Pipeline embolization device.[Abstract] [Full Text] [Related] [New Search]