These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Inter- and intra-tester reliability of sensibility testing in digital nerve repair.
    Author: Bulut T, Akgun U, Ozcan C, Unver B, Sener M.
    Journal: J Hand Surg Eur Vol; 2016 Jul; 41(6):621-3. PubMed ID: 26685154.
    Abstract:
    The aim of this study was to investigate the inter- and intra-tester reliability of the static two-point discrimination and Semmes-Weinstein monofilament tests in digital nerve repair. A total of 100 digital nerves from 67 patients were included into the study. An experienced orthopaedic surgeon and a physiotherapist examined the sensory nerve recovery. The reproducibility score of both tests was at a poor level, but the reliability of the Semmes-Weinstein monofilament test was higher than the static two-point discrimination test. These tests should not be used alone in the quantitative monitoring of sensory recovery, but should be interpreted with the clinical findings.Level 3 non-randomized controlled study.
    [Abstract] [Full Text] [Related] [New Search]