These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Radiosynthesis of clinical doses of ⁶⁸Ga-DOTATATE (GalioMedix™) and validation of organic-matrix-based ⁶⁸Ge/⁶⁸Ga generators. Author: Tworowska I, Ranganathan D, Thamake S, Delpassand E, Mojtahedi A, Schultz MK, Zhernosekov K, Marx S. Journal: Nucl Med Biol; 2016 Jan; 43(1):19-26. PubMed ID: 26702783. Abstract: INTRODUCTION: 68Ga-DOTATATE is a radiolabeled peptide-based agonist that targets somatostatin receptors overexpressed in neuroendocrine tumors. Here, we present our results on validation of organic matrix 68Ge/68Ga generators (ITG GmbH) applied for radiosynthesis of the clinical doses of 68Ga-DOTATATE (GalioMedixTM). METHODS: The clinical grade of DOTATATE (25 μg±5 μg) compounded in 1 M NaOAc at pH=5.5 was labeled manually with 514±218 MBq (13.89±5.9 mCi) of 68Ga eluate in 0.05 N HCl at 95°C for 10 min. The radiochemical purity of the final dose was validated using radio-TLC. The quality control of clinical doses included tests of their osmolarity, endotoxin level, radionuclide identity, filter integrity, pH, sterility and 68Ge breakthrough. RESULTS: The final dose of 272±126 MBq (7.35±3.4 mCi) of 68Ga-DOTATATE was produced with a radiochemical yield (RCY) of 99%±1%. The total time required for completion of radiolabeling and quality control averaged approximately 35 min. This resulted in delivery of 50%±7% of 68Ga-DOTATATE at the time of calibration (not decay corrected). CONCLUSIONS: 68Ga eluted from the generator was directly applied for labeling of DOTA-peptide with no additional pre-concentration or pre-purification of isotope. The low acidity of 68Ga eluate allows for facile synthesis of clinical doses with radiochemical and radionuclide purity higher than 98% and average activity of 272±126 MBq (7.3±3 mCi). There is no need for post-labeling C18 Sep-Pak purification of final doses of radiotracer. Advances in knowledge and implications for patient care. The clinical interest in validation of 68Galabeled agents has increased in the past years due to availability of generators from different vendors (Eckert-Ziegler, ITG, iThemba), favorable approach of U.S. FDA agency to initiate clinical trials, and collaboration of U.S. centers with leading EU clinical sites. The list of 68Ga-labeled tracers evaluated in clinical studies should growth because of the sensitivity of PET technique, the simplicity of the shakebake approach for the dose preparation and reliability of 68Ge/68Ga generators. Our studies have confirmed the reproducible elution profile, and high reliability of ITG GmbH generators required for routine doses preparation according to FDA recommendations.[Abstract] [Full Text] [Related] [New Search]