  • Title: Exposure to anesthetic waste gas in oral surgery.
    Author: Campbell RL, Hannifan MA, Reist PC, Gregg JM.
    Journal: J Oral Surg; 1977 Aug; 35(8):625-30. PubMed ID: 267187.
    Abstract:
    Exposure to nitrous oxide and halothane during oral surgery was monitored using a Miran infrared analyzer. A "typical" time-weighted analysis exposure was established for the surgeon, assistant, and anesthetist. Values for halothane ranged from 7.5 to 59 ppm, and for nitrous oxide, from 280 to 90,000 ppm.