These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Differential pathlength factor estimation for brain-like tissue from a single-layer Monte Carlo model.
    Author: Chatterjee S, Phillips JP, Kyriacou PA.
    Journal: Annu Int Conf IEEE Eng Med Biol Soc; 2015; 2015():3279-82. PubMed ID: 26736992.
    Abstract:
    A Monte Carlo simulation-based computational model has been developed for tracing the pathway of light within a single layer of tissue like bloodless human brain. A reflectance mode source-detector geometry is assumed to illuminate the tissue slab with an irradiation of a near infrared wavelength and to detect the re-emitted light intensity. Light is considered to be attenuated within tissue by scattering and absorption. The model has been used to predict the relationship of mean optical path of photons with variable source-detector geometry and thus, to determine a differential pathlength factor (DPF) of 5.66 for incident light of wavelength 810 nm.
    [Abstract] [Full Text] [Related] [New Search]