These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Extended Swan-Neck Catheter With Upper Abdominal Exit-Site Reduces Peritoneal Dialysis-Related Infections.
    Author: Eriguchi M, Tsuruya K, Yoshida H, Haruyama N, Tanaka S, Tsuchimoto A, Fujisaki K, Torisu K, Masutani K, Kitazono T.
    Journal: Ther Apher Dial; 2016 Apr; 20(2):158-64. PubMed ID: 26762798.
    Abstract:
    Extended catheters with an upper abdominal exit-site (UAE) are reportedly associated with a lower incidence of peritoneal dialysis (PD)-related infections. However, little information about the optimal peritoneal catheter configuration for UAE is available. In this nonrandomized multicenter trial, 147 consecutive cases of a UAE involving either a conventional straight (CS; 80 cases) or extended swan-neck catheter (SN; 67 cases) were analyzed to compare exit-site and tunnel infections (ESTI), peritonitis, and catheter survival. The ESTI-free and catheter survival rates were significantly lower in the SN than in the CS group (P <0.01). However, the peritonitis-free survival rate was not different (P = 0.26). In terms of analyses for infection rates, fewer episodes of ESTI (1.284 vs 0.608 episodes/patient-year; P <0.01) and peritonitis (0.345 vs 0.152 episodes/patient-year; P = 0.06) were observed in the SN than CS group. Recurrence analyses showed that the mean number of cumulative episodes of ESTI and peritonitis between two groups were significantly different.
    [Abstract] [Full Text] [Related] [New Search]