These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Durability and clinical impact of tricuspid valve procedures in patients receiving a continuous-flow left ventricular assist device.
    Author: Han J, Takeda K, Takayama H, Kurlansky PA, Mauro CM, Colombo PC, Yuzefpolskaya M, Fukuhara S, Truby LK, Topkara VK, Garan AR, Mancini DM, Naka Y.
    Journal: J Thorac Cardiovasc Surg; 2016 Feb; 151(2):520-7.e1. PubMed ID: 26806510.
    Abstract:
    OBJECTIVE: Patients evaluated for a continuous-flow left ventricular assist device frequently present with severe right ventricular dysfunction with tricuspid regurgitation. Long-term outcomes of concurrent tricuspid valve procedures in continuous-flow left ventricular assist device implantation are unclear. METHODS: From May 2004 to December 2013, 336 patients received continuous-flow left ventricular assist devices. Among these, 8 patients with prior tricuspid valve procedures were excluded. At continuous-flow left ventricular assist device implantation, 76 patients underwent tricuspid valve procedures (group A), including 68 repairs and 8 replacements. The remaining 252 patients did not receive concurrent tricuspid valve procedures (group B). RESULTS: Preoperatively, group A had higher central venous pressure/pulmonary capillary wedge pressure (P = .032), total bilirubin (P = .009), and percentage of moderate or greater tricuspid regurgitation (98.7% vs 18.8%; P < .001). In group A, cardiopulmonary bypass time (136 ± 52.0 minutes vs 83.9 ± 38.8 minutes; P < .001), intraoperative platelet use (13.6 ± 6.70 units vs 11.7 ± 5.92 units; P = .042), and bleeding requiring reoperation (27.5% vs 16.7%; P = .046) were significantly increased. In-hospital mortality was similar (10.5% vs 6.4%; P = .22). On-device 2-year survival was 73.9% in group A and 74.2% in group B (P = .24). At 2 years, mean cumulative readmissions for right heart failure was 0.21 in group A and 0.27 in group B (P = .95). A generalized linear mixed-effects model showed that tricuspid valve procedures are protective for developing future significant tricuspid regurgitation (odds ratio, 0.38; 95% confidence interval, 0.19-0.76; P = .006). CONCLUSIONS: Concomitant tricuspid valve procedures at continuous-flow left ventricular assist device implantation can be performed safely and are protective against worsening tricuspid regurgitation during the first 2 years of support.
    [Abstract] [Full Text] [Related] [New Search]