  • Title: Impending rupture of saphenous vein graft aneurysm with floating fractured bare metal stent treated by coil embolization and covered stent implantation.
    Author: Kodama A, Kurita T, Kato O, Suzuki T.
    Journal: Heart Vessels; 2016 Nov; 31(11):1882-1885. PubMed ID: 26815559.
    Abstract:
    Aneurysmal degeneration of a saphenous vein graft (SVG) is a rare, but potentially fatal complication of coronary artery bypass graft (CABG) surgery. In this case report, a patient that had undergone prior CABG surgery and bare metal stent (BMS) implantation at the site of a stenotic SVG lesion presented at our hospital with chest pain, and an SVG aneurysm was detected at the previous BMS implantation site. In addition, the implanted BMS was fractured and floating in the SVG aneurysm. The SVG aneurysm was successfully occluded by percutaneous intervention, using a combination of distal covered stent deployment at the site of the anastomosis between the native coronary artery and the SVG and proximal coil embolization of the aneurysm.