These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Transesophageal Echocardiographic Measurement of Cardiac Index by the Prosthetic Mitral Valve Method Is Not Similar to the Continuous Thermodilution Method Via a Pulmonary Artery Catheter. Author: Shi H, Wang Z, Wei H, Ge Y, Chen X. Journal: J Cardiothorac Vasc Anesth; 2016 Apr; 30(2):398-405. PubMed ID: 26830650. Abstract: OBJECTIVE: To compare the agreement of cardiac index measurements between transesophageal echocardiography across the prosthetic mitral valve and the continuous thermodilution method through a pulmonary artery catheter (PAC-TD) in patients undergoing double-valve replacement. DESIGN: Observational prospective study. SETTING: University hospital. PARTICIPANTS: Twenty-five patients undergoing double-valve replacement (12 men and 13 women, age 25-78 years, ASA III-IV, NYHA II-III, LVEF≥45%). Patients were grouped according to their prosthesis (mechanical prosthesis v bioprosthesis). INTERVENTIONS: All patients underwent cardiac index assessment during double-valve replacement. MEASUREMENTS AND MAIN RESULTS: Cardiac index across the prosthetic mitral valve was measured simultaneously using transesophageal echocardiography (CI(MV)) and PAC-TD (CI(PAC)) at 15, 30, 45, and 60 minutes after weaning from cardiopulmonary bypass, and at 0, 15, and 30 minutes after incision closure. A correlation was present between CI(MV) and CI(PAC) in both groups (mechanical prosthesis: r = 0.47, p<0.01; bioprosthesis: r = 0.60, p<0.01). In the mechanical prosthesis group, the bias between techniques (CI(PAC) v CI(MV)) was-0.5 L/min/m(2) (95% CI:-1.97 to 0.97), and error was 55%. In the bioprosthesis group, the bias between both techniques was-1.3 L/min/m(2) (95% CI:-3.1 to 0.5), and error was 56%. CONCLUSIONS: A relatively weak correlation and lack of agreement between values of CI(PAC) and CI(MV) were observed in patients undergoing double-valve replacement. Therefore, transesophageal echocardiography might not be interchangeable with PAC-TD for measuring cardiac output or cardiac index. A regression equation is needed to correct the probable value of CI(PAC). CI(MV) might be useful as a quantitative or semi-quantitative cardiac output measurement.[Abstract] [Full Text] [Related] [New Search]